A flex duct to connect to the ducts and provide a hole to mount a fan.
Air duct pressure testing equipment.
Our duct leakage testers are compliant with the following standards.
You can rest assured that our expert technicians will deliver the quality problem solving mindset and quality service you would expect from a trusted partner.
En 1507 ventilation for buildings sheet metal air ducts with rectangular section requirements for strength and leakage.
Pole rd everson wa 98225.
Providing unparalleled customer service and rapid care to our valuable customers is what drives us at rapid duct testing.
The instrument provides step by step test configuration and automated leakage testing based on the smacna hvac air duct leakage test manual and is accurate to 2 5 of reading.
If the test is at 6 static pressure for leakage class 3 compliance i e 9 6 cfm per 100 s f with 6 orifice differential and 6 duct test pressure the meter could only indicate 24 cfm.
Eurovent 2 2 leakage rate in sheet metal air distribution systems.
A calibrated fan capable of creating a measurable flow of air.
Our services rapid duct testing has been working with contractors corporations and homeowners within southern california for over a decade in providing superior services mandated by title 24 california energy commission.
Though built tough with an on board powerful motor the dalt 6900 is very easy to transport on its pneumatic tires and leaves little to no footprint on the job site.
Conducting a test determines if there are unsealed cracks resulting in air leakages that require immediate sealing.
However the blower for the test apparatus would have to produce 24 cfm at 10 to 12 static.
Duct pressure and leakage testing baroscopic investigation of systems static pressure profiles at matrix air balance we bring you an unmatched level of testing technical skills and knowledge paired with the most.
A two channel differential pressure gauge that can also calculate flow for a particular fan.
A fan speed controller to change the air flow.
En 12237 ventilation for buildings ductwork strength and leakage of circular sheet metal ducts.
Retrotec eu hardermaat 12 7244pz barchem netherlands 31 0 522 282941.
At matrix air balance we bring you an unmatched level of testing technical skills and knowledge paired with the most advanced duct pressure testing equipment to your project.
In order to ensure that you have a quality heating and cooling system in your building we carry out the following tests.
A typical duct leakage testing system is comprised of four main parts.
Packaged with the tsi velocicalc 9565 p and dp calc micromanometer 5825 the pan200 series offers real time leakage rate calculations monitors barometric pressure and temperature generates a pass fail result and simplifies report generation and documentation by downloading stored data.